In this article
Which procedures apply to lifts
The Ordinance on the Essential Requirements and Conformity Assessment of Lifts and Safety Components for Lifts transposes Directive 2014/33/EU and lists the procedures in Art. 10(1):
- for lifts designed and manufactured to a model lift that has passed EU-type examination (module B): final inspection, module E or module D;
- for lifts designed and manufactured under an approved quality system under Section V of Annex 4: again final inspection, module E or module D;
- unit verification (module G);
- full quality assurance plus design examination (module H1).
Where the party responsible for design and manufacture differs from the party that installs and tests the lift, the former supplies the latter with all documents needed for correct and safe installation and testing (Art. 10(2)).
Table of lift modules
The Directive and the Bulgarian ordinance number their annexes differently. The table shows how the two numberings match.
| Procedure | Module | Directive annex | Bulgarian ordinance |
|---|---|---|---|
| EU-type examination of lifts | B | IV, Part B | Annex 4, Section I |
| Final inspection | – | V | Annex 4, Section VI |
| Product quality assurance | E | X | Annex 4, Section III |
| Production quality assurance | D | XII | Annex 4, Section II |
| Unit verification | G | VIII | Annex 4, Section IV |
| Full quality assurance plus design examination | H1 | XI | Annex 4, Section V |
What the notified body checks under each module
- Module B. The body examines the technical design of a model lift and a representative sample of a complete lift. The sample must include the loading landings and serve at least three levels – top, middle and bottom (Annex 4, Section I, points 1–2). If successful, an EU-type examination certificate is issued. The body keeps a copy and the documentation for 15 years (point 6).
- Final inspection. Documents are checked and the lift is tested: operation empty and at maximum load, functioning of the safety components including on power failure, and a static test at 1.25 times the rated load. The body then checks for deformation or wear (Annex 4, Section VI, point 3.3). It issues a final inspection certificate and fills in the lift logbook (point 4).
- Module G. The body reviews the technical documentation and the lift. Tests include at least those of final inspection, and the result is a certificate of conformity (Section IV, point 4).
- Module E. The body assesses the installer’s quality system for final product inspection and testing (Section III).
- Module H1. The quality system for design, manufacture, assembly, installation, inspection and testing is assessed, and where appropriate the lift design (Section V). The Directive provides for periodic audits and possible unannounced visits (Annex XI).
Procedures for safety components for lifts
For the safety components listed in Annex 1, Art. 9 allows three routes:
- EU-type examination (module B, Annex 3, Section I = Directive Annex IV, Part A), followed by conformity to type with random checking (module C2, Annex IX);
- module B followed by product quality assurance (module E, Annex VI);
- full quality assurance (module H, Annex 3, Section IV = Annex VII).
ESTIMA KM is notified for module H (Annex VII) for all types of safety components in Annex III, and for module B (Annex IV, Part A) and module C2 (Annex IX) only for devices to prevent falls (Annex III, point 2). For the other types, module B, and for all types, module E (Annex VI), can only be carried out by another notified body. More in our article on safety components.
How to choose a procedure
- A one-off lift to an individual design – can be assessed under module G, with no prior type examination (Art. 10(1)(3)).
- A series of lifts to one model – module B for the model, then final inspection of each lift, or module E or D for the quality system. All permitted variants are described with maximum and minimum values (Art. 10(3)).
- An installer with its own design and a certified quality system – module H1.
On every route, the notified body’s number follows the CE marking in the car (Art. 13(6)). Each application goes to one notified body only. Certificates issued under the previous rules (Directive 95/16/EC) remain valid (§ 5(3) of the Transitional and Final Provisions; Art. 44 of the Directive).
To apply under one of our procedures, see notified body No. 1829 or write to us via ESTIMA KM offices.
Need conformity assessment for a lift?
Call or write to us.
Sofia: +359 2 951 54 53 Notified Body 1829Write to office@estimakm.com
Sources
- Ordinance on the Essential Requirements and Conformity Assessment of Lifts and Safety Components for Lifts — Art. 9; Art. 10; Art. 13, para. 5–6; annex No. 3, sections I–IV; annex No. 4, sections I–VI; § 5 of the Transitional and Final Provisions
- Directive 2014/33/EU on lifts and safety components for lifts — Art. 15, 16, 44; annexes IV–XII
- NANDO / Single Market Compliance Space — ESTIMA KM entry (No. 1829) — notification under 2014/33/EU
This article is for information and does not replace the text of the legal act.